Radiated and conducted emission test
We perform radiated emission tests and conducted emission tests
from electrical and electronic equipment. Below are the test items
and frequency ranges that we can test.
Test item |
Frequency range |
Radiated emission test |
30Hz~40GHz |
Conducted emission test |
10kHz~30MHz |
Power harmonic corrent test |
- |
Power supply voltage fluctuation
test / flicker test |
- |
Below are the test standards that we can test and the external
certification bodies that have certified those standards.
Please contact us regarding tests other than those listed below.
EMI test standard |
*Certified body |
VCCI-CISPR32 |
NVLAP / VCCI |
CISPR32 / EN55032 |
NVLAP |
CISPR 11 / EN55011 |
NVLAP |
ANSI C63.4 (47 CFR FCC Part 15 Sub part B) |
NVLAP / FCC |
IEC / EN / JIS C 61000-3-2 |
|
IEC / EN / JIS C 61000-3-3 |
|
Electrical Safety Act Ministerial Ordinance Paragraph 1
Technical Standards Attached table 8 |
|
GR 1089 |
|
Various ability measurments |
|
*Certified as an ISO/IEC 17025 testing laboratory by NVLAP
( 2002-2023/9/15 ) and FCC ( 1990-2023/12/31 ).
It was also certified by VCCI ( 1989-2024/3/31 ).
We perform immunity tests on products in various electromagnetic
environments.
Below are the test items and frequency ranges that we can test.
Test item |
Frequency range |
Testable level |
Electrostatic discharge test |
- |
0.01~27kV |
Radiation immunity test |
0.01~80MHz |
1~10V/m AM modulation |
80~690MHz |
1~10V/m AM modulation |
690~6000MHz |
1~20V/m AM modulation |
6000~18000MHz |
1~10V/m pulse modulation |
Electrical first transient test |
- |
0.1~4kV |
Surge immunity test |
- |
200~6600V |
Conduction immunity test |
150kHz~ 80MHz |
1~10Vemf |
Power frequency magnetic field test |
- |
1~30A/m |
Voltage dips, short interruption test |
- |
- |
Immunity test are conducted based on the test standards below.
Below are the test standards that we can test and the external
certification bodies that have certified those standards.
Please contact us regarding test other than those listed
below immunity test standars,product standards.
イミュニティ試験規格、製品規格 |
*認定機関 |
IEC / EN 61000-4-2 Electrostatic discharge test |
NVLAP |
IEC / EN 61000-4-3 Radiation immunity test |
NVLAP |
IEC / EN 61000-4-4 Electrical first transient test |
|
IEC / EN 61000-4-5 Surge immunity test |
|
IEC / EN 61000-4-6 Conduction immunity test |
|
IEC / EN 61000-4-8 Pow frequency magunetic field test |
|
IEC / EN 61000-4-11 Voltage dips, short interruption test |
|
IEC / EN 61326-1 |
|
CISPR35 / EN55035 |
|
IEC / EN 61000-6-2 |
|
GR1089 |
|
Various ability test |
|
*Certified as an ISO/IEC 17025 testing laboratory by